Core Cable Spiral wound resistance wire on fiberglass core
Insulation Silicon rubber of a radial wall thickness 0.80mm rated at 150oC Dialectic strength………500v per mm Insulation resistance...>20 megaohms at 3300v immersed in saline
Cold Tails 0.75mm double insulated appliance wire rated at 90oC
Terminals Nickel silver or brass, insulated with adhesive lined Polyolefin heat shrink tubing, water resistant
Factory Tests Resistance tolerance +/- 5% at 20oC Insulation test. 10kv test following extrusion of insulation
Protective Coatings Fibreglass mesh medium and/or covered with Fosroc premium grade cement based self-levelling compound. Application thickness 1-6mm
Temperature Limited - when installed to specifications the Warmfloor Heating cable surface does not exceed 35oC
|